DI-QCIC-80864
Scanning Electron Microscope Analysis Report
The Scanning Electron Microscope (SEM) Analysis Report documents the quality and acceptability of metallization on semiconductor dice, addressing batch-process-oriented metallization defects.
Approval DateJune 22, 1989
AMSC NumberG4767
Preparing Activity—
Project Number—
OPRG/Y253
DTIC Applicable—
GIDEP Applicable—
Limitation—
Applicable Forms—
Approval Limitation—
Form VersionMAR 87
DID Formatdd_form_1664
963C CompliantNo
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
Description & Purpose
The purpose of the Scanning Electron Microscope (SEM) Analysis Report is to document the quality and acceptability of metallization on semiconductor dice. It addresses the specific metallization defects that are batch process orientated and that can best be identified utilizing this method.
Application & Interrelationship
This Data Item Description (DID) contains the format and content preparation instructions for the data product resulting from the work task described in MIL-STD-883, Method 2018.
Preparation Instructions
10.1Reference documents.The applicable issue of the documents cited herein, including their approval dates and dates of any applicable amendments, notices, revisions, shall be as specified in the contract.
10.2Format.The report may be in the contractor's format.
10.3Content.Refer to MIL-STD-883, Method 2018, for additional content clarification. The report shall include the following:
10.3.1Title page.The title page shall contain:
10.3.1.1Title of the report
10.3.1.2Contract name and number
10.3.1.3Contractor's name
10.3.1.4Date of document preparation
10.3.1.5Names of individuals who prepared the report
10.3.1.6Security classification
10.3.2Photographs.There shall be a minimum of three photographs per lot. Two photographs shall show the worst case oxide steps and one photograph shall the worst case general metallization. If any photograph shows another apparent defect within the field of view, another photograph shall be included to certify the extent of the apparent defect.
10.3.3Photograph information.The following information shall be traceable to each photograph:
10.3.3.1Manufacturer's lot identification number
10.3.3.2SEM operator/inspector's identification
10.3.3.3Date of SEM report.
10.3.3.5Device/circuit identification (type or part number)
10.3.3.6Area of photographic documentation
10.3.3.8Electron beam accelerating voltage